{"title":"Autoclaves","description":"","products":[{"product_id":"autoclave-8-litres-classe-b-avec-usb","title":"8 Liter Class B Autoclave with USB","description":"\u003ch2\u003e 8 litre white autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\r \n- A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 170 x 320 mm\u003cbr\u003e\n - Tray size: 130 x 265 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\r \n- External dimensions: 420 x 370 x 525 mm\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMaintaining Your Autoclave:\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eThe Error Message Guide\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\r \n- 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\r \n4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51507672252734,"sku":"49.001","price":2067.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67078.png?v=1743102796"},{"product_id":"autoclave-12-litres-classe-b-avec-usb-rose","title":"12 Litre Class B Autoclave with USB Pink","description":"\u003ch2\u003e12 litre pink autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\r \n\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\r \n- Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51507672580414,"sku":"49.002","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67098.png?v=1743102820"},{"product_id":"autoclave-18-litres-classe-b-avec-usb","title":"18 Liter Class B Autoclave with USB","description":"\u003ch2\u003e18 litre white autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\r \n\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 350 mm\u003cbr\u003e\n - Tray size: 192 x 285 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 600 mm\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\r \n- Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51507672809790,"sku":"49.003","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67085.png?v=1743102832"},{"product_id":"autoclave-23-litres-classe-b-avec-usb","title":"23 Litre Class B Autoclave with USB","description":"\u003ch2\u003e23 litre white autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\r \n\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 450 mm\u003cbr\u003e\n - Tray size: 192 x 380 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2200W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 690 mm\u003cbr\u003e\n - Net weight: 53 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\r \n- Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 4. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 6. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 7. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 9. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51507680805182,"sku":"49.004","price":2795.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67101.png?v=1743103028"},{"product_id":"autoclave-12-litres-classe-b-avec-usb","title":"12 Litre Class B Autoclave with USB","description":"\u003ch2\u003e 12 litre white autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\r \n- Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508065993022,"sku":"49.005","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67117.png?v=1743108585"},{"product_id":"autoclave-18-litres-classe-b-avec-usb-vert","title":"18 Liter Class B Autoclave with USB Green","description":"\u003ch2\u003e 18 litre green autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\r \n- Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 350 mm\u003cbr\u003e\n - Tray size: 192 x 285 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 600 mm\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508066484542,"sku":"49.006","price":2470.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67092.png?v=1743108606"},{"product_id":"autoclave-8-litres-classe-b-avec-usb-noir","title":"8 Litre Class B Autoclave with USB Black","description":"\u003ch2\u003e Black 8 liter autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\r \n- Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 170 x 320 mm\u003cbr\u003e\n - Tray size: 130 x 265 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\r \n- Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 525 mm\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\r \n- Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\r \n3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508068745534,"sku":"49.007","price":2132.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67123.png?v=1743108666"},{"product_id":"autoclave-12-litres-classe-b-avec-usb-noir","title":"12 Litre Class B Autoclave with USB Black","description":"\u003ch2\u003eBlack autoclave 12 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\r \n\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\r \n- Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508069564734,"sku":"49.008","price":2236.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/67095.png?v=1743108677"},{"product_id":"filtre-bacteriologique-de-rechange-pour-autoclave","title":"Replacement Bacteriological Filter for Autoclave","description":"\u003cp\u003e Bacteriological filter for class B autoclave\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":51508133560638,"sku":"33.412","price":35.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/53182_22273fde-60d0-4a5d-a7aa-8b67e26676a0.jpg?v=1743109843"},{"product_id":"filtre-interne-de-rechange-pour-autoclave","title":"Replacement Internal Filter for Autoclave","description":"\u003cp\u003e Replacement Internal Filter for Autoclave\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":51508133724478,"sku":"33.413","price":20.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/5476_c58a2a4d-f252-4825-868f-b8f98002993a.jpg?v=1743109850"},{"product_id":"gant-en-silicone-autoclaves-ruck","title":"Silicone Glove - Autoclaves - Ruck","description":"\u003cp\u003e Silicone gripping gloves, especially for the safe removal of sterilization trays. The gripping slats on the sides protect against slipping.\u003c\/p\u003e\n\n\n \u003cp\u003e\u003c\/p\u003e\n\n\n\u003cp\u003eDurable, heat-resistant, and insensitive silicone material. This glove is also suitable for cooking.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e Sterilizable at 134°C\u003cbr\u003e\n\u003c\/p\u003e\n\n","brand":"Ruck","offers":[{"title":"Default Title","offer_id":51508263485758,"sku":"47.815","price":20.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/9241_3519b54a-37c6-4ea3-bfdc-a530e3d1c502.jpg?v=1743113204"},{"product_id":"joint-de-porte-pour-autoclave-icanclave","title":"Door seal for Icanclave autoclave","description":"\u003cp\u003e Please note that the color of the seal may change depending on arrivals.\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"8 L","offer_id":51508393017662,"sku":"49.009.01","price":61.5,"currency_code":"EUR","in_stock":true},{"title":"12 L","offer_id":51508393050430,"sku":"49.009.02","price":68.5,"currency_code":"EUR","in_stock":true},{"title":"18 L \u0026amp; 23 L","offer_id":51508393083198,"sku":"49.009.03","price":71.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/83535.png?v=1743116875"},{"product_id":"cle-du-reglage-de-la-porte-pour-autoclave-my-podologie","title":"Autoclave Door Adjustment Key - My Podologie","description":"\u003ch2\u003e Autoclave door adjustment key\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eGeneral characteristics:\u003c\/strong\u003e\u003cbr\u003e\n • Ideal for properly adjusting the Icanclave autoclave door\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":51508498039102,"sku":"33.1020","price":29.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/83806.png?v=1743119481"},{"product_id":"autoclave-enbio-s-2-7-litres","title":"Enbio S autoclave - 2.7 liters","description":"\u003ch2\u003eEnbio S - 2.7 litre ultra-fast Class B autoclave for sterilizing surgical instruments\u003c\/h2\u003e\n\n\u003cp\u003e \u003cspan style=\"color: rgb(0, 159, 148);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Garantie_Autoclave_Enbio.pdf?v=1719931091\" title=\"Enbio Autoclave Guarantee\" style=\"color: rgb(0, 0, 0);\" rel=\"noopener\" target=\"_blank\"\u003eEnbio Autoclave Guarantee\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca rel=\"noopener\" title=\"Pro User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Manuel_d_utilisation_Enbio_Pro_et_S.pdf?v=1719930861\" style=\"color: rgb(0, 0, 0);\" target=\"_blank\"\u003eEnbio User Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" href=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/b0f56f0017a64f1c842ba2e2e0a410bf.mp4\" target=\"_blank\"\u003eVIDEO INSTALLATION\u003c\/a\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e \u003ca style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Maintenance_Enbio_S_Enbio_Pro.pdf?v=1753342777\" target=\"_blank\"\u003eMAINTENANCE\u003c\/a\u003e\n\u003c\/div\u003e\n\n \u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Nettoyage_du_generateur_de_vapeur_Enbio.pdf?v=1753342900\" target=\"_blank\"\u003eSTEAM GENERATOR CLEANING\u003c\/a\u003e\u003c\/div\u003e\n\n\u003cp\u003e\u003cbr\u003e Enbio S is a\u003cmeta charset=\"utf-8\"\u003e A sterilizer that is simple to use, compact and easy to install.\u003cbr\u003e\u003cbr\u003e ENBIO autoclaves are up to 6 times smaller and up to 3 times lighter than typical Class B autoclaves, while being just as efficient.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eFeatures :\u003c\/strong\u003e\u003cbr\u003e • Class B\u003cbr\u003e • Fast cycle\u003cbr\u003e •\u003cmeta charset=\"utf-8\"\u003e 2.7 liter capacity: can hold up to 8 sterilization pouches or instruments directly in bulk\u003cbr\u003e • \u003cspan\u003eCompact format (25 x 16 x 56 cm)\u003c\/span\u003e \u003cbr\u003e• Quiet: 40 dB. You can sterilize your instruments while seeing patients in your office without them even noticing it's running\u003cbr\u003e • Water supply: The Enbio S autoclave uses \u003cstrong\u003edistilled water\u003c\/strong\u003e from an external reservoir\u003cbr\u003e • Power supply: works with any standard electrical outlet\u003cbr\u003e • Data archiving: all process data is automatically saved to a USB drive; no manual saving is required.\u003cbr\u003e • Process reports: software dedicated to reading and printing process data\u003cbr\u003e • Interior tray dimensions:\u003cmeta charset=\"utf-8\"\u003e 28 x 18 x 3.5 cm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e • Warranty: 1-year warranty + 1-year extension if Enbio maintenance is performed within 12 months \/ 1500 cycles \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Garantie_Autoclave_Enbio.pdf?v=1728988400\" title=\"Learn more about the Enbio guarantee\" rel=\"noopener\" target=\"_blank\"\u003e. Learn more\u003c\/a\u003e\u003cbr\u003e • Swiss Made\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n \u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e3 sterilization programs:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable style=\"width: 500px; height: 161px;\" cellspacing=\"1\" cellpadding=\"1\" border=\"1\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\n\u003ctd style=\"height: 19.5938px; width: 93.375px;\"\u003e Program\u003c\/td\u003e\n\n\u003ctd style=\"height: 19.5938px; width: 85.4219px;\"\u003e 134°C FAST\u003c\/td\u003e\n\n\u003ctd style=\"height: 19.5938px; width: 103.016px;\"\u003e 134°C\u003c\/td\u003e\n\n\u003ctd style=\"height: 19.5938px; width: 103.016px;\"\u003e 121°C \u003c\/td\u003e\n\n\u003ctd style=\"height: 19.5938px; width: 87.1719px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\n\u003ctd style=\"height: 55.1875px; width: 93.375px;\"\u003e\n\n\u003cp\u003eTotal sterilization time\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd style=\"height: 55.1875px; width: 85.4219px;\"\u003e 10 min\u003c\/td\u003e\n\n\u003ctd style=\"height: 55.1875px; width: 103.016px;\"\u003e 18 min\u003c\/td\u003e\n\n\u003ctd style=\"height: 55.1875px; width: 103.016px;\"\u003e 30 min \u003c\/td\u003e\n\n\u003ctd style=\"height: 55.1875px; width: 87.1719px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\n\u003ctd style=\"height: 58.7812px; width: 93.375px;\"\u003e Load type\u003c\/td\u003e\n\n\u003ctd style=\"height: 58.7812px; width: 85.4219px;\"\u003e instruments in bulk\u003c\/td\u003e\n\n\u003ctd style=\"height: 58.7812px; width: 103.016px;\"\u003e Instruments packaged\/unpackaged\u003c\/td\u003e\n\n\u003ctd style=\"height: 58.7812px; width: 103.016px;\"\u003e Instruments packaged\/unpackaged \u003c\/td\u003e\n\n\u003ctd style=\"height: 58.7812px; width: 87.1719px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"height: 10px;\"\u003e\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e Unlike the Enbio Pro,\u003cspan\u003e \u003c\/span\u003eEnbio S does not complete the prion cycle\u003c\/p\u003e","brand":"Enbio","offers":[{"title":"White","offer_id":51508498661694,"sku":"271.001.01","price":2388.0,"currency_code":"EUR","in_stock":true},{"title":"Gray","offer_id":51508498694462,"sku":"271.001.02","price":2388.0,"currency_code":"EUR","in_stock":false},{"title":"Blue","offer_id":51508498727230,"sku":"271.001.03","price":2388.0,"currency_code":"EUR","in_stock":false},{"title":"YELLOW","offer_id":51508498759998,"sku":"271.001.04","price":2388.0,"currency_code":"EUR","in_stock":false},{"title":"Pink","offer_id":51508498792766,"sku":"271.001.05","price":2388.0,"currency_code":"EUR","in_stock":false},{"title":"Black Edition","offer_id":51508498825534,"sku":"271.001.06","price":2388.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/75056_094edb1c-93f2-4622-abfa-a756dac25f19.jpg?v=1743119510"},{"product_id":"autoclave-enbio-pro-5-3-litres","title":"Enbio Pro autoclave - 5.3 liters","description":"\u003ch2\u003e Enbio Pro ultra-fast Class B autoclave for sterilizing surgical instruments\u003c\/h2\u003e\n\n\u003cp\u003e \u003cspan style=\"color: rgb(0, 159, 148);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" rel=\"noopener\" title=\"Enbio Autoclave Guarantee\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Garantie_Autoclave_Enbio.pdf?v=1728988400\" target=\"_blank\"\u003eEnbio Autoclave Guarantee\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e \u003cbr\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Manuel_d_utilisation_Enbio_Pro_et_S.pdf?v=1719930861\" title=\"Pro User Manual\" rel=\"noopener\" target=\"_blank\"\u003eEnbio Pro User Manual\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/b0f56f0017a64f1c842ba2e2e0a410bf.mp4\" style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" target=\"_blank\"\u003eVIDEO INSTALLATION\u003c\/a\u003e\u003c\/div\u003e\n\n \u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Maintenance_Enbio_S_Enbio_Pro.pdf?v=1753342777\" style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" target=\"_blank\"\u003eMAINTENANCE\u003c\/a\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e \u003ca style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Nettoyage_du_generateur_de_vapeur_Enbio.pdf?v=1753342900\" target=\"_blank\"\u003eSTEAM GENERATOR CLEANING\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cbr\u003e Enbio Pro is a simple to use, compact and easy to install autoclave.\u003cbr\u003e\u003cbr\u003e THE  \u003cmeta charset=\"utf-8\"\u003eENBIO sterilizers are up to 6 times smaller and up to 3 times lighter than typical Class B autoclaves, while being just as effective.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eFeatures :\u003c\/strong\u003e\u003cbr\u003e • Class B\u003cbr\u003e • Fast cycle\u003cbr\u003e • 5.3 liter capacity: can hold up to 16 sterilization pouches or instruments directly in bulk\u003cbr\u003e • External dimensions: L 56 x W 27 x H 20 cm\u003cbr\u003e • Quiet: 40 dB. You can sterilize your instruments while seeing patients in your office without them even noticing it's running\u003cbr\u003e • Water supply: The Enbio Pro autoclave uses \u003cstrong\u003edistilled water\u003c\/strong\u003e from an external reservoir\u003cbr\u003e • Power supply: works with any standard electrical outlet\u003cbr\u003e • Data archiving: all process data is automatically saved to a USB drive; no manual saving is required. \u003cbr\u003e• Process reports: software dedicated to reading and printing process data\u003cbr\u003e • Interior tray dimensions: 28 x 18 x 7 cm\u003cbr\u003e • Warranty: 1-year warranty + 1-year extension if Enbio maintenance is performed within 12 months \/ 1500 cycles \u003ca rel=\"noopener\" title=\"Learn more about the Enbio guarantee\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Garantie_Autoclave_Enbio.pdf?v=1728988400\" target=\"_blank\"\u003e. Learn more\u003c\/a\u003e\u003cbr\u003e • Swiss Made\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp style=\"text-align: center;\"\u003e \u003cstrong\u003e4 sterilization programs:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 500px;\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Program\u003c\/td\u003e\n\n\u003ctd\u003e 134°C FAST\u003c\/td\u003e\n\n\u003ctd\u003e 134°C\u003c\/td\u003e\n\n\u003ctd\u003e 121°C\u003c\/td\u003e\n\n\u003ctd\u003e 134°C PRION\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp\u003e Total sterilization time\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e 10 min\u003c\/td\u003e\n\n\u003ctd\u003e 18 min\u003c\/td\u003e\n\n\u003ctd\u003e 30 min\u003c\/td\u003e\n\n\u003ctd\u003e 43 min\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Load type\u003c\/td\u003e\n\n\u003ctd\u003e instruments in bulk\u003c\/td\u003e\n\n\u003ctd\u003e Instruments packaged\/unpackaged\u003c\/td\u003e\n\n\u003ctd\u003e Instruments packaged\/unpackaged\u003c\/td\u003e\n\n\u003ctd\u003e Packaged instruments\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Drying\u003c\/td\u003e\n\n\u003ctd\u003e -\u003c\/td\u003e\n\n\u003ctd\u003e Yes\u003c\/td\u003e\n\n\u003ctd\u003e Yes\u003c\/td\u003e\n\n\u003ctd\u003e Yes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Class\u003c\/td\u003e\n\n\u003ctd\u003e S\u003c\/td\u003e\n\n\u003ctd\u003e B\u003c\/td\u003e\n\n\u003ctd\u003e B\u003c\/td\u003e\n\n\u003ctd\u003e B - PRION\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Power: 230V\/50Hz\u003cbr\u003e • Installed power: 3250 W\u003cbr\u003e • Maximum power consumption: 15 A\u003cbr\u003e • Working pressure: 2.1 bar\u003cbr\u003e • Maximum pressure: 2.3 bar \u003cbr\u003e• Maximum process temperature: 138°C\u003cbr\u003e • Sterilization volume: 5.3 l\u003cbr\u003e • Approximate maximum number of packs: 16\u003cbr\u003e • Maximum load weight: 0.8 kg\u003cbr\u003e • Weight: 20 kg\u003cbr\u003e • Degree of protection: IP20\u003cbr\u003e • Process data storage: USB drive\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eOptional accessory - The Enbio magic filter:\u003c\/strong\u003e\u003cbr\u003e The Magic Filter allows the autoclave to reuse wastewater during the sterilization process. By using this filter, you'll no longer have to worry about constantly replacing bottles of demineralized or distilled water. The Magic Filter will save you 400 liters of water, equivalent to 80 five-liter containers.\u003cbr\u003e This product is designed to reduce waste, water consumption, and environmental impact. This accessory is not included with the purchase of the autoclave.\u003c\/p\u003e\n\n\u003cp style=\"text-align: center;\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Enbio","offers":[{"title":"Default Title","offer_id":51508500365630,"sku":"271.002","price":2871.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/64214.png?v=1743119564"},{"product_id":"poignee-de-porte-pour-autoclave-icanclave","title":"Door handle for icanclave autoclave","description":"\u003cp\u003e Replacement door handle for all icanclave class B autoclaves.\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508520059198,"sku":"33.1039","price":55.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/62968_3110d34c-952b-45bc-ab9c-4191f2b84117.jpg?v=1743120223"},{"product_id":"autoclave-blanc-8-litres-classe-b-avec-usb-et-imprimante-integree","title":"8 Litre White Autoclave Class B with USB and integrated printer","description":"\u003ch2\u003e 8 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 420 x 370 x 525 mm\u003cbr\u003e\n - Tray dimensions: 265 x 130 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic autoclave operating symbols, such as door position, water level, sterilization program, date, and time, will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508559806782,"sku":"49.014","price":2067.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/69548.png?v=1743121095"},{"product_id":"autoclave-blanc-12-litres-classe-b-avec-usb-et-imprimante-integree","title":"12 Litre Class B White Autoclave with USB and Integrated Printer","description":"\u003ch2\u003e 12 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\r \n- Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 420 x 370 x 595 mm\u003cbr\u003e\n - Tray dimensions: 315 x 160 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic autoclave operating symbols, such as door position, water level, sterilization program, date, and time, will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508559872318,"sku":"49.015","price":2171.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/69549.png?v=1743121103"},{"product_id":"autoclave-blanc-18-litres-classe-b-avec-usb-et-imprimante-integree","title":"White Autoclave 18 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 18 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\r \n- Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 600 mm\u003cbr\u003e\n - Tray dimensions: 285 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508560134462,"sku":"49.016","price":2405.0,"currency_code":"EUR","in_stock":false}]},{"product_id":"autoclave-blanc-23-litres-classe-b-avec-usb-et-imprimante-integree","title":"23 Litre Class B White Autoclave with USB and Integrated Printer","description":"\u003ch2\u003e 23 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\r \n- Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 690 mm\u003cbr\u003e\n - Tray dimensions: 380 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 53 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508560167230,"sku":"49.017","price":2795.0,"currency_code":"EUR","in_stock":false}]},{"product_id":"autoclave-blanc-29-litres-classe-b-avec-usb-et-imprimante-integree","title":"29 Litre Class B White Autoclave with USB and Integrated Printer","description":"\u003ch2\u003e 29 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not properly closed.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and generator\u003cbr\u003e\r \n- An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off the electrical energy if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Fault alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 860 mm\u003cbr\u003e\n - Tray dimensions: 380 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 2300W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5°C \/ 40°C\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 65 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\r \n- Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and error message guide for your autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for removing the trays\u003cbr\u003e\r \n- Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\r \n4. Turning on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic autoclave operating symbols, such as door position, water level, sterilization program, date, and time, will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Prepare the material to be sterilized: Place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure drops to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Caution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":51508561117502,"sku":"49.018","price":4420.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/69690.png?v=1743121162"},{"product_id":"filtre-de-rechange-pour-distillateur-deau","title":"Replacement filter for water distiller","description":"\u003ch2\u003e Replacement filter for water distiller\u003c\/h2\u003e\n\n\n\u003cp\u003e Filter to be changed every 2 months\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":51508805140798,"sku":"33.918","price":5.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/files\/82953.png?v=1743125296"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0867\/6923\/8334\/collections\/1310.jpg?v=1742824271","url":"https:\/\/www.podologic.fr\/en\/collections\/autoclaves.oembed?page=2","provider":"Podologic","version":"1.0","type":"link"}